(1) Electric heating wire The arrangement must not cross, overlap, or knot.
(2) Electric heating wire The resistor and power rating are specified; the live wire must be connected in parallel, not in series. Do not extend or shorten it, as this may prevent the heating element from generating heat, cause it to burn out, or even damage the power cord.
(3) Electric heating wire It must be used only in soil or water; do not perform electrical testing or use it in the air. Otherwise, insulation may be damaged, sintering may occur, short circuits or wire breaks may result, and fire could even be ignited.
(4) Electric heating wire At one end, connect to the live wire; at the other end, connect to the neutral wire. (When the three-phase, three-wire power supply is 380 V, connect the two ends to the phase conductors.) During wiring, both ends of the electric heating cable should be positioned at the end adjacent to the seedlings and must not be separated, to facilitate connection of the power supply, thermostat, AC contactor, and other components. The heating cable has an even number of leads. At each end of the electric heating cable, there is a section of non‑heating power lead. The junction between the power lead and the heating cable must be installed above ground and should not be buried underground to prevent electrical leakage.
(5) Electric heating wire It can be directly connected to the power supply via a switch rated for equivalent power. This method is simple and low-cost, but temperature control is difficult. The heating cable requires manual on/off operation, demanding that users be highly responsible and have ample time. Heating cables connected in this manner are typically used only during severe cold seasons and when intense cold air masses arrive.
(6) When using a temperature controller to automatically regulate the seedbed temperature, the total power of the heating elements connected to the controller must not exceed the controller’s rated load capacity. The load power of a typical temperature controller is generally below 2,000 watts, corresponding to 10 amperes. If… Electric heating wire Total power exceeds For a 2000-watt load, an AC contactor should be connected to prevent damage to the thermostat’s built-in relay. The AC contactor and thermostat should be installed inside the distribution box in a well-ventilated, dry location.
(7) If there is no 220 V AC power supply near the seedbed and only a three-phase, four-wire 380 V AC supply is available, use an AC contactor to switch between the phase conductors when operating. Frequent manual switching can be hazardous. With a three-phase, four-wire 380 V supply, it is clear which conductor is the neutral. When the neutral is properly connected, the voltage between the neutral and any one of the other three phase conductors is 220 V AC. In this way, the 380 V supply can be converted into a 220 V supply. If the load on a phase conductor is substantial—exceeding 10,000 W, or 50 A or more—it should be evenly distributed among three separate phase conductors; high‑power loads must not be connected to a single phase. Otherwise, the three-phase equipment downstream may overheat, resulting in reduced rotor speed, noise, overheating, and diminished performance.