Common Problems and Solutions for Electric Heating Tubes
Release Date:
2021-03-08
Author:
Abstract:
Electric heating tubes are common heating elements in electrical components, capable of converting electrical energy into heat. Due to their low cost, ease of installation, and lack of pollution, they are widely used in various heating applications. But what should you do if something goes wrong?
Below are some common malfunctions and their troubleshooting methods that we have summarized:
Fault 1: No fever
Fault analysis: power supply abnormalities or power outages; blown fuse; poor contact between the power cord plug and the outlet, or an open circuit in the power cord conductor; short circuit caused by a loose connection at the heating element terminal or a disconnected wire; damaged heating element; poor contact or melting of the thermostat contacts.
Remedial measures: Use the device after the power supply has been restored; replace with a fuse of the same type; repair or replace the component; resolder the connection; replace the electric heating element with one of the same specifications; repair or replace the component.
Fault 2: Fuse blown
Fault analysis: The fuse diameter is too small, resulting in insufficient current-carrying capacity; the power cord plug is shorted to the power outlet; the heating element connector or wiring has come loose, causing a short circuit; the heating element… ( Resistance wire ) or cause a short circuit; dust or carbonization inside electric heating sockets can lead to short circuits.
Troubleshooting steps: Replace with a suitable fuse; repair or replace the power plug or outlet; reconnect securely; repair or replace as needed; clean away dirt, and repair or replace any damaged parts.
Fault 3: Thermostat malfunction
Fault analysis: the ceramic contact rod of the thermostat is jammed by foreign matter; the thermal bimetal has deformed; the moving and stationary contacts have suffered fatigue and loss of elasticity; the moving and stationary contacts are seized, preventing opening or closing; the fastening screws of the moving and stationary contacts have loosened.
Treatment methods: Remove foreign objects and gently move the component up and down with your fingers; correct any deformation to restore its original shape and elasticity; adjust the contact angle to regain elasticity; grind away worn contact points, and if this does not work, replace the part; finally, retighten.
Fault 4: Leakage current
Fault analysis: Ground wire connection; excessive dust on the power outlet or power plug; circuit wiring has come loose and is colliding with the cup body; heating element. ( Heating wire ) Insulation failure; electric heating tube ( Heating wire ) Burnout, resulting in a short circuit with the cup body; improper cleaning, leading to ingress into the junction box.
Remedial measures: Connect the grounding wire as required; clean and dry the equipment; inspect for any detached wires and re-solder them; repair or replace faulty components; replace with electric heating tubes of the same specifications; or, if appropriate, switch to a cleaning and drying procedure.